Risk and Safety phrases


R and S phrases


Hazard classification should be indicated with hazard signs and hazard symbols and/or R phrases as well as S phrases.
  • R phrase and R number: phrases indicating the risks of hazardous preparations and substances, and their numbers respectively.
  • S phrase and S number: phrases related to the safe handling of hazardous preparations, and their numbers respectively.

Risk Phrases (R) and Safety Phrases (S) also occur in combinations (combined R and S phrases).

R and S Phrases are separated with dashes or slashes which mean the following:
  • Dash: R Phrases and S Phrases are formulated separately
  • Slash : the possibility of formulating R Phrases or S Phrases in a single sentence (combined R or S Phrases)

It is a general rule that in case of preparations usually a maximum of 6 phrases are applied to inform about the risks; in this respect combined phrases are regarded as single phrases.

The sentences that are applied should inform about all significant hazards of the preparation, therefore in some cases more than 6 R Phrases may be necessary.

The R Phrases on the label as well as the method and aim of the preparation’s intended use should be taken into account in the final choice of S Phrases.

As a general rule, a maximum of 6 sentences are used to inform about the most necessary precautions; in this respect combined phrases are regarded as single phrases.

In some cases more than 6 S Phrases may be necessary.

RISK PHRASES
DESIGNATED HAZARDOUS SUBSTANCES
NOHSC:10005(1999)
R01- Explosive when dry.
R02-Risk of explosion by shock, friction, fire or other sources of ignition.
R03- Extreme risk of explosion by shock, friction, fire or other sources of ignition.
R04- Forms very sensitive explosive metallic compounds.
R05- Heating may cause an explosion.
R06- Explosive with or without contact with air.
R07- May cause fire.
R08- Contact with combustible material may cause fire.
R09- Explosive when mixed with combustible material.
R10- Flammable.
R11- Highly Flammable.
R12-Extremely Flammable.
R14- Reacts violently with water.
R15- Contact with water liberates extremely flammable gases.
R16- Explosive when mixed with oxidising substances.
R17- Spontaneously flammable in air.
R18- In use may form flammable/explosive vapour air mixture.
R19- May form explosive peroxides.
R20- Harmful by inhalation.
R20/21- Harmful by inhalation and in contact with skin.
R20/21/22- Harmful by inhalation, in contact with skin and if swallowed.
R20/22- Harmful by inhalation and if swallowed.
R21- Harmful in contact with skin.
R21/22- Harmful in contact with skin and if swallowed.
R22- Harmful if swallowed.
R23- Toxic by inhalation.
R23/24- Toxic by inhalation and in contact with skin.
R23/24/25- Toxic by inhalation, in contact with skin and if swallowed.
R23/25- Toxic by inhalation and if swallowed.
R24- Toxic in contact with skin.
R24/25- Toxic in contact with skin and if swallowed.
R25- Toxic if swallowed.
R26- Very toxic by inhalation.
R26/27- Very toxic by inhalation and in contact with skin.
R26/27/28- Very toxic by inhalation, in contact with skin and if swallowed.
R26/28- Very toxic by inhalation and if swallowed.
R27- Very toxic in contact with skin.
R27/28- Very toxic in contact with skin and if swallowed.
R28- Very toxic if swallowed.
R29- Contact with water liberates toxic gas.
R31- Contact with acids liberates toxic gas.
R32- Contact with acids liberates very toxic gas.
R33- Danger of cumulative effects.
R34- Causes burns.
R35- Causes severe burns.
R36- Irritating to eyes.
R36/37- Irritating to eyes and respiratory system.
R36/37/38- Irritating to eyes, respiratory system and skin.
R36/38- Irritating to eyes and skin.
R37- Irritating to respiratory system.
R37/38- irritating to respiratory system and skin.
R38- Irritating to skin.
R39- Danger of very serious irreversible effects.
R39/23- Toxic: danger of very serious irreversible effects through inhalation.
R39/23/24- Toxic: danger of very serious irreversible effects through inhalation and in
contact with skin.
R39/23/24/25- Toxic: danger of very serious irreversible effects through inhalation, in contact
with skin and if swallowed.
R39/23/25- Toxic: danger of very serious irreversible effects through inhalation and if
swallowed.
R39/24- Toxic: danger of very serious irreversible effects in contact with skin.
R39/24/25- Toxic: danger of very serious irreversible effects in contact with skin and if
swallowed.
R39/25- Toxic: danger of very serious irreversible effects if swallowed.
R39/26- Very toxic: danger of very serious irreversible effects through inhalation.
R39/26/27- Very toxic: danger of very serious irreversible effects through inhalation and in
contact with skin.
R39/26/27/28- Very toxic: danger of very serious irreversible effects through inhalation, in
contact with skin and if swallowed.
R39/26/28- Very toxic: danger of very serious irreversible effects through inhalation and if
swallowed.
R39/27- Very toxic: danger of very serious irreversible effects in contact with skin.
R39/27/28- Very toxic: danger of very serious irreversible effects in contact with skin and if
swallowed.
R39/28- Very toxic: danger of very serious irreversible effects if swallowed.
R40- Possible risks of irreversible effects.
R40/20- Harmful: possible risk of irreversible effects through inhalation.
R40/20/21- Harmful: possible risk of irreversible effects through inhalation and in contact
with skin.
R40/20/21/22- Harmful: possible risk of irreversible effects through inhalation, in contact with
skin and if swallowed.
R40/20/22- Harmful: possible risk of irreversible effects through inhalation and if
swallowed.
R40/21- Harmful: possible risk of irreversible effects in contact with skin.
R40/21/22- Harmful: possible risk of irreversible effects in contact with skin and if
swallowed.
R40/22- Harmful: possible risk of irreversible effects if swallowed.
R41- Risk of serious damage to eyes.
R42- May cause sensitisation by inhalation.
R42/43- May cause sensitisation by inhalation and skin contact.
R43- May cause sensitisation by skin contact.
R45- May cause cancer.
R46- May cause heritable genetic damage.
R48- Danger of serious damage to health by prolonged exposure.
R48/20- Harmful: danger of serious damage to health by prolonged exposure through
inhalation.
R48/20/21/22- Harmful: danger of serious damage to health by prolonged exposure through
inhalation, in contact with skin and if swallowed.
R48/20/22- Harmful: danger of serious damage to health by prolonged exposure through
inhalation and if swallowed.
R48/20/2l- Harmful: danger of serious damage to health by prolonged exposure through
inhalation and in contact with skin.
R48/21- Harmful: danger of serious damage to health by prolonged exposure in contact
with skin.
R48/21/22- Harmful: danger of serious damage to health by prolonged exposure in contact
with skin and if swallowed.
R48/22- Harmful: danger of serious damage to health by prolonged exposure if
swallowed.
R48/23- Toxic: danger of serious damage to health by prolonged exposure through
inhalation.
R48/23/24- Toxic: danger of serious damage to health by prolonged exposure through
inhalation and in contact with skin.
R48/23/24/25- Toxic: danger of serious damage to health by prolonged exposure through
inhalation, in contact with skin and if swallowed.
R48/23/25- Toxic: danger of serious damage to health by prolonged exposure through
inhalation and if swallowed.
R48/24- Toxic: danger of serious damage to health by prolonged exposure in contact
with skin.
R48/24/25- Toxic: danger of serious damage to health by prolonged exposure in contact
with skin and if swallowed.
R48/25- Toxic: danger of serious damage to health by prolonged exposure if swallowed.
R49- May cause cancer by inhalation.
R50- Very toxic to aquatic organisms.
R51- Toxic to aquatic organisms.
R52- Harmful to aquatic organisms.
R53- May cause long term adverse effects in the aquatic environment.
R54- Toxic to flora.
R55- Toxic to fauna.
R56- Toxic to soil organisms.
R57- Toxic to bees.
R58- May cause long term adverse effects in the environment.
R59- Dangerous for the ozone layer.
R60 -May impair fertility
R61 -May cause harm to the unborn child.
R62 -Possible risk of impaired fertility.
R63 -Possible risk of harm to the unborn child.
R64 -May cause harm to breastfed babies.
R65 -Harmful: May cause lung damage if swallowed.

SAFETY PHRASES
DESIGNED HAZARDOUS SUBSTANCES
NOHSC:10005(1999)
S01 -Keep locked up.
S010/2- Keep locked up and out of the reach of children.
S02- Keep out of the reach of children.
S03- Keep in a cool place.
S03/07- Keep container tightly closed in a cool place.
S03/09/14- Keep in a cool well ventilated place away from (incompatible materials to be
indicated by manufacturer).
S03/09/14- Keep only in the original container in a cool well ventilated place away from
(incompatible materials to be indicated by the manufacturer).
S03/09/49- Keep only in the original container in a cool well ventilated place.
S03/14- Keep in a cool place away from (incompatible materials to be indicated by the
manufacturer).
S04- Keep away from living quarters.
S05- Keep contents under (there follows the name of a liquid).
S06- Keep under (there follows the name of an inert gas).
S07- Keep container tightly closed.
S07/47- Keep Container tightly closed and at a temperature not exceeding *C (to be
specified by manufacturer).
S07/8- Keep container tightly closed and dry.
S07/9- Keep container tightly closed and in a well ventilated place.
S08- Keep container dry.
S09- Keep container in a well-ventilated place.
S12- Do not keep the container sealed.
S13- Keep away from food, drink and animal foodstuffs.
S14- Keep away from (a list of incompatible materials will follow).
S15- Keep away from heat.
S16- Keep away from sources of ignition.
S17- Keep away from combustible material.
S18- Handle and open container with care.
S20- When using, do not eat or drink.
S20/21- When using do not eat, drink or smoke.
S21- When using do not smoke.
S22- Do not breathe dust.
S23- Do not breathe vapour.
S24- Avoid contact with skin.
S24/25- Avoid contact with skin and eyes.
S25- Avoid contact with eyes.
S26- In case of contact with eyes, rinse immediately with plenty of water and seek
medical advice.
S27- Take off immediately all contaminated clothing.
S28- After contact with skin, wash immediately with plenty of soap-suds.
S29- Do not empty into drains.
S29/56- Do not empty into drains, dispose of this material and its container to hazardous
or special waste collection point.
S30- Never add water to this product.
S33- Take precautionary measures against static discharges.
S35- This material and its container must be disposed of in a safe way.
S36- Wear suitable protective clothing.
S36/37- Wear suitable protective clothing and gloves.
S36/37/39- Wear suitable protective clothing, gloves and eye / face protection.
S36/39- Wear suitable protective clothing and eye/face protection.
S37- Wear suitable gloves.
S37/39- Wear suitable gloves and eye/face protection.
S38- In case of insufficient ventilation, Wear suitable respiratory equipment.
S39- Wear eye / face protection.
S40- To clean the floor and all objects contaminated by this material, use – (there
follows suitable cleaning material).
S41- In case of fire and / or explosion do not breathe fumes.
S42- During fumigation / spraying wear suitable respiratory equipment.
S43- In case of fire use (there follows the type of fire fighting equipment to be used.)
S45- In case of accident or if you feel unwell, seek medical advice immediately
(show the label whenever possible.).
S46- If swallowed, seek medical advice immediately and show this container or
label.
S47- Keep at temperature not exceeding.
S47/49- Keep only in the original container at temperature not exceeding *C (to be
specified by manufacturer).
S48- To be kept wet with (there follows a material name).
S49- Keep only in the original container.
S50- Do not mix with.
S51- Use only in well ventilated areas.
S52- Not recommended for interior use on large surface areas.
S53- Avoid exposure - obtain special instructions before use.
S56- Dispose of this material and its container at hazardous or special waste
collection point.
S57- Use appropriate container to avoid environmental contamination.
S59- Refer to manufacturer / supplier for information on recovery recycling.
S60- This material and its container must be disposed of as hazardous waste.
S61- Avoid release to the environment. Refer to special instructions/safety data
sheets.
S62- If swallowed, do not induce vomiting; seseek medical advice immediately and
show this container or label.




Monday, 14 April 2014

Disaster Plan

Disaster Plan

Disaster Plan usually involves four phases :
1. Prevention
2. Preparedness
3. Response
4. Recovery

The following guide to producing a disaster plan outlines recommended action in all four phases, but prevention is the best protection against disaster, natural or man-made.

Phase 1 : Prevention
Identify and minimize the risks posed by the building, its equipment and fittings, and the natural hazards of the area.

• Carry out a building inspection and alter factors which constitute a potential hazard.
• Establish routine housekeeping and maintenance measures to withstand disaster in buildings and
surrounding areas.
• Install automatic fire detection and extinguishing systems, and water-sensing alarms.
• Take special precautions during unusual periods of increased risk, such as building renovation.
• Make special arrangements to ensure the safety of library or archival material when exhibited.
• Provide security copies of vital records such as collection inventories, and store these off-site.
• Protect computers and data through provision of uninterrupted power supply.
• Have comprehensive insurance for the library or archives, its contents, the cost of salvage operations, and potential replacement, re-binding and restoration of damaged materials.

Phase 2 : Preparedness
Getting ready to cope.

• Develop a written preparedness, response and recovery plan.
• Keep the plan up-to-date, and test it.
• Keep together supplies and equipment required in a disaster and maintain them.
• Establish and train an in-house disaster response team. Training in :
− disaster response techniques,
− identification and marking on floor-plans and enclosures of irreplaceable and important material for priority salvage.
• Prepare and keep an up-to-date set of documentation including :
− Building floor-plans, with locations of cut-off switches and valves.
− Inventory of holdings, with priorities for salvage marked on floor-plans.
− List of names, addresses, and home telephone numbers of personnel with emergency responsibilities.
− List of names, addresses, and home telephone numbers of the in-house disaster response team.
− List of names, addresses and home telephone numbers of trained conservators with experience in salvaging water-damaged materials, resource organisations, and other facilities able to offer support in the event of a disaster.
− List of disaster control services, in-house supplies and equipment, and in any central store, including locations and names of contacts with home telephone numbers.
− List of suppliers of services and sources of additional equipment and supplies, including names of contacts and home telephone numbers.
− Arrangements made to access freezing facilities.
− Arrangements for funding emergency needs.
− Copies of insurance policies.
− Salvage procedures.
• Distribute the plan and documentation to appropriate locations on- and off-site.
• Institute procedures to notify appropriate people of the disaster and assemble them rapidly.

Phase 3 : Response
When disaster strikes.

• Follow established emergency procedures for raising the alarm, evacuating personnel and making the disaster site safe
• Contact the leader of the disaster response team to direct and brief the trained salvage personnel
• When permission is given to re-enter the site, make a preliminary assessment of the extent of the damage, and the equipment, supplies and services required.
• Stabilize the environment to prevent the growth of mould.
• Photograph damaged materials for insurance claim purposes.
• Set up an area for recording and packing material which requires freezing, and an area for airdrying slightly wet material and other minor treatment.
• Transport water-damaged items to the nearest available freezing facility.

Phase 4 : Recovery
Getting back to normal.

• Establish a programme to restore both the disaster site and the damaged materials to a stable and usable condition.
• Determine priorities for restoration work and seek the advice of a conservator as to the best methods and options, and obtain cost estimates.
• Develop a phased conservation programme where large quantities of material are involved.
• Discard items not worth retaining, and replace or re-bind items not justifying special conservation treatment.
• Contact insurers.
• Clean and rehabilitate the disaster site.
• Replace treated material in the refurbished site.
• Analyse the disaster and improve the plan in the light of experience.
– Be prepared for any type of disaster. Contact and consult other libraries or archives and library or archives associations to share information and experience, and with a view to regional cooperation.
– Take advantage of educational sessions, particularly disaster planning workshops and preparedness exercises.

Monday, 17 March 2014

Theory Of Accident Causes

THEORY OF ACCIDENT CAUSES


Accidents are defined as unplanned occurrences which result in injuries, fatalities, loss of production or damage to property and assets. Preventing accidents is extremely difficult in the absence of an understanding of the causes of accidents. Many attempts have been made to develop a prediction theory of accident causation, but so far none has been universally accepted. Researchers from different fields of science and engineering have been trying to develop a theory of accident causation which will help to identify, isolate and ultimately remove the factors that contribute to or cause accidents. In this article, a brief outline of various accident causation theories is presented, followed by a structure of accidents.

Accident Causation Theories
The domino theory
According to W.H. Heinrich (1931), who developed the so-called domino theory, 88 of all accidents are caused by unsafe acts of people, 10% by unsafe actions and 2% by “acts of God”. He proposed a “five-factor accident sequence” in which each factor would actuate the next step in the manner of toppling dominoes lined up in a row. The sequence of accident factors is as follows:
1. Ancestry and social environment
2. Worker fault
3. Unsafe act together with mechanical and physical hazard
4. Accident
5. Damage or injury.
In the same way that the removal of a single domino in the row would interrupt the sequence of toppling, Heinrich suggested that removal of one of the factors would prevent the accident and resultant injury; with the key domino to be removed from the sequence being number 3. Although Heinrich provided no data for his theory, it nonetheless represents a useful point to start discussion and a foundation for future research.
Multiple causation theory
Multiple causation theory is an outgrowth of the domino theory, but it postulates that for a single accident there may be many contributory factors, causes and sub-causes, and that certain combinations of these give rise to accidents. According to this theory, the contributory factors can be grouped into the following two categories:
Behavioral. This category includes factors pertaining to the worker, such as improper attitude, lack of knowledge, lack of skills and inadequate physical and mental condition.
Environmental. This category includes improper guarding of other hazardous work elements and degradation of equipment through use and unsafe procedures.
The major contribution of this theory is to bring out the fact that rarely, if ever, is an accident the result of a single cause or act.
The pure chance theory
According to the pure chance theory, every one of any given set of workers has an equal chance of being involved in an accident. It further implies that there is no single discernible pattern of events that leads to an accident. In this theory, all accidents are treated as corresponding to Heinrich’s acts of God, and it is held that there exist no interventions to prevent them.
Biased liability theory
Biased liability theory is based on the view that once a worker is involved in an accident, the chances of the same worker becoming involved in future accidents are either increased or decreased as compared to the rest of workers. This theory contributes very little, if anything at all, towards developing preventive actions for avoiding accidents.
Accident proneness theory
Accident proneness theory maintains that within a given set of workers, there exists a subset of workers who are more liable to be involved in accidents. Researchers have not been able to prove this theory conclusively because most of the research work has been poorly conducted and most of the findings are contradictory and inconclusive. This theory is not generally accepted. It is felt that if indeed this theory is supported by any empirical evidence at all, it probably accounts for only a very low proportion of accidents without any statistical significance.
The energy transfer theory
Those who accept the energy transfer theory put forward the claim that a worker incurs injury or equipment suffers damage through a change of energy, and that for every change of energy there is a source, a path and a receiver. This theory is useful for determining injury causation and evaluating energy hazards and control methodology. Strategies can be developed which are either preventive, limiting or ameliorating with respect to the energy transfer.
Control of energy transfer at the source can be achieved by the following means:
· Elimination of the source
· Changes made to the design or specification of elements of the work station
· Preventive maintenance.
The path of energy transfer can be modified by:
· Enclosure of the path
· Installation of barriers
· Installation of absorbers
· Positioning of isolators.
The receiver of energy transfer can be assisted by adopting the following measures:
· Limitation of exposure
· Use of personal protective equipment.

The “symptoms versus causes” theory
The “symptoms versus causes” theory is not so much a theory as an admonition to be heeded if accident causation is to be understood. Usually, when investigating accidents, we tend to fasten upon the obvious causes of the accident to the neglect of the root causes. Unsafe acts and unsafe conditions are the symptoms-the proximate causes-and not the root causes of the accident.
Structure of Accidents
The belief that accidents are caused and can be prevented makes it imperative for us to study those factors which are likely to favour the occurrence of accidents. By studying such factors, the root causes of accidents can be isolated and necessary steps can be taken to prevent the recurrence of the accidents. These root causes of accidents can be grouped as “immediate” and “contributing”. The immediate causes are unsafe acts of the worker and unsafe working conditions. The contributing causes could be management-related factors, the environment and the physical and mental condition of the worker. A combination of causes must converge in order to result in an accident.
Below figure shows the structure of accidents, including the details of immediate causes, contributing causes, types of accidents and results of accidents. This accounting is not exhaustive by any means. However, an understanding of the “cause and effect” relation of the accident-causing factors is required before continuous improvement of safety processes can be undertaken.

                                                                  Structure of accidents


Summary
Accident causation is very complex and must be understood adequately in order to improve accident prevention. Since safety lacks a theoretical base, it cannot be regarded as being a science yet. This fact should not discourage us, as most of the scientific disciplines-mathematics, statistics and so on-passed through a similarly tentative phase at one time or the other. Accident causation study holds great promise for those who are interested in developing the pertinent theory. At present, theories of accident causation are conceptual in nature and, as such, are of limited use in preventing and controlling accidents. With such a diversity of theories, it will not be difficult to understand that there does not exist one single theory that is considered right or correct and is universally accepted. These theories are nonetheless necessary, but not sufficient, for developing a frame of reference for understanding accident occurrences.


Saturday, 8 February 2014

Objectives of Fire safe Building Design

Objectives of fire safe building design

Effective fire safe design begins with conscious analysis and decision-making early in the design process. To effectively incorporate the building fire defenses into the design the fire safety objective must first be identified.
The acceptable levels of safety and the focus of fire safety analysis and design process objectives are concentrated in the following areas.
  1.      Life safety
  2.          Property protection
  3.          Continuity of operation
  4.          Environmental protection

Fire Safety Design Strategy
Fire safety objective can be met if fire ignition can be prevented or if, given ignition, the fire can be managed. Evaluating a design for building fire safety represent a systematic approach to the fire safety strategy. These strategies can be identified as follows:
1. Prevent fire ignitionn
The first opportunity to achieve fire safety in a building is through fire prevention, which involves separating potential heat sources from potential fuels. Major building fires are started by heat sources and ignitable materials that are brought into the building, not built into it. This means the design of the building, from the architects and builder’s standpoint provides limited potential leverage on building future fire experience.
2. Control combustion Process
The control combustion process is concerned with slowing the fire to provide other fire safety measures with sufficient time to be effective. The building fire safety system can be organized around fire growth and its resulting production of combustion i.e. flame, heat smoke ad gases. The ease of generation and movement of these products is influenced by counter measure provided by the building. The effectiveness of the building fire safety system determines the speed, quantity and paths of movement of these products of combustion.
The main factors that influence the control of combustion process are
  1.      Fuel load
  2.           Interior finish of the room
  3.        Air supply
  4.        Size and shape and construction of the room
  5.        Fire load

3. Control fire by construction
Fire Resistance Barriers such as walls, partition and floors, separate building spaces. These barriers also delay or prevent fire from propagation from one place to another. In addition, barriers are important features in any fire fighting operation because they dictate the size of fire.
The effectiveness of a barrier depends upon its inherent fire resistance construction and its penetration. Use of flame retardant paints, fire stop barriers, firewalls, fire doors and windows. Other few methods for controlling the fires by construction in building.
4. Fire detection and alarms
Fire detection is needed so that automatic or manual fires suppression will be initiated, any other active fire protection system will be activated and occupants will have time to move to safe locations typically outside the building.
5. Automatic suppression
To accomplish automatic suppression, both detecting the fire and applying sufficient suppressant are necessary. The major elements of determining the automatic extinguishing system are
  1.        Its presence or absence
  2.        If present, its reliability
  3.        If reliability its designing and extinguishing effectiveness.

6. Manual suppression
The major aspect of this part of building design include
i.
Fire department’s distance from building
ii.
Initial agent application
iii.
Fire extinguishment
iv.
Ventilation
v.
Water storage and use
vi.
Water removable
vii.
Barrier effectiveness
7. Managing the exposed
Fire impact can be lessened by managing the exposed i.e. people property, operations, environment or heritage depending on the design aspects being considered. The exposed people or property may be safeguarded either moving them to a safe area or refuge or by defending them in a place. The design for life safety may involve one or combination of
  1.        Evacuation of the occupants
  2.        Defending the occupants in place
  3.        Providing an effective area of refuge
  4.        Practicing evacuation drill


Safety requirements for high raised buildings

The susceptibility of buildings to fire depends on several factors like:
  1.        Type and size of building,
  2.        method of construction,
  3.        combustibility of materials of construction,
  4.        the type of occupancy,
  5.        age of the building,
  6.        degree of fire resistance,
  7.        the type of building services,
  8.        fire load. of the building,
  9.        fire prevention, and fire protection arrangements of the building,
  10.           scores of others, including the human factor.

 However, for purposes of analysis of the various fire hazards in buildings it is common to divide these hazards into:
(i) Internal hazards- which arise inside the building and which concern the safety of the occupants (Personal Hazard or more widely known as Life Hazard): and which concerns the safety of the structure and the contents; and
(ii) External hazards - which arise as a result of fires in surrounding property (Exposure Hazard)
The relative degree of each of these hazards will vary according to the type of occupancy of the building - An Assembly occupancy will be having predominently life hazards, whereas a Storage occupancy will have primarily a damage hazard, ie., hazard to the structure and contents.

Fire and Damage Hazards to the Building that needs to be considered for safety requirements for high raised buildings:
The other internal hazard arising from fires within the building is the damage hazard or the hazard to the building structure and contents.
Many factors can have a bearing on this form of internal hazard such as:
  1.        The type of building construction,
  2.        Fire resistance of the elements of structure,
  3.        Combustibility of materials of construction,
  4.         Unbroken large spaces,
  5.        Fire load of the building,
  6.        Open vertical and horizontal shafts,
  7.        Bad house-keeping and storage practices,
  8.        Unsafe processes,
  9.        Non-availability of fire doors and other types of fire barriers
  10.           Inadequate fire fighting/fire protection measures,
  11.          Unsafe building services,
  12.          Unfavourable human elements etc.. 

Hazards from building services
1.     Electrical installations
2.     Heating
3.     Ventilation
4.     Air conditioning
5.     Refuse disposal
6.     Plumbing,
7.     Communications,
8.     Transportation and conveyance systems.

Design Considerations of Egress of a building:

Designing a means of egress involves more than numbers, flow rates and densities. Good exits facilitate everyone to leave the fire area in the shortest possible time by prompt and efficient use of them. If the fire is discovered promptly and occupants alerted also equally promptly, early evacuation can be done. However, evacuation times are directly related to the fire hazard; higher the hazard, shorter the exit time.
Provision of two separate means of exits for every floor including basements is a fundamental requirement, except in very few deserving cases.
In general, life safety from fire requires the following principles to be adopted:(Some of these may have already been covered earlier):

  1.     Sufficient number of unobstructed exits of adequate capacity and properly designed, with easy access;
  2.     Safeguarding of exits against fire and smoke during the length of time they are designed for use;
  3.     Availability of alternate exit and means of access to it, in case one exit is unusable due to fire;
  4.    Sub division of areas to provide sufficient areas of refuge for occupants where evacuation may be delayed;
  5.    Adequate protection of vertical openings to minimize hazards from fire and smoke;
  6.    Efficient fire alarm systems for alerting occupants and others concerned in case of fire;
  7.   Adequate lighting of exits and rescue paths;
  8.   Adequate exit indication signs to help evacuation;
  9.    Ensuring trouble free evacuation through the escape route by safeguarding of equipment and vulnerable areas from fire and smoke hazards;
  10.    Fully rehearsed exit drill procedures to ensure orderly and smooth exit;
  11.    Institution of panic control measures;
  12. Control fire hazards from interior finish material.
EXITS
Exits are a critical part of overall life safety. Several basic concepts are involved in determining the number, arrangement, and construction of exits for a specific area.

The details of some of the means of exit or egress or escape is a continuous path of travel from any point in a building or structure to the open air outside at ground level. It consists of three constituents which are:
(i) the exit access;
(ii) the exit ;
(iii) the exit discharge
The main requirements for the means of exit consisting of the three constituents as given above are:
  1.  All means of exit, including staircases, lift lobbies and corridors, shall be adequately ventilated;
  2. Exits not properly ventilated can cause suffocation to people being evacuated because a large number of people would be present in such enclosed place with no natural ventilation till they get out of it and reach open air;
  3. Every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of occupants, in case of fire or other emergency;
  4. An exit may be a doorway, corridor, passageway(s) to an internal staircase, or external staircase, or to a verandah or terrace(s), which have access to the street, or to the roof of a building or a refuge area. An exit may also include a horizontal exit leading to an adjoining building at the same level;
  5. Every exit, exit access or exit discharge shall be continuously maintained free of all obstructions or impediments to full use in the case of fire or other emergency.
  6. Even if adequate exits are provided at the initial stage, often at the time of renovation/alteration, knowingly or unknowingly, people do not give same attention to exit requirements. In view of the above this requirement assumes great significance.
  7.  No building shall be so altered as to reduce the number, width or protection of exits to less than that required.
  8. People escaping from areas filled with fire and smoke will be all anxiety to reach open air where they can breath normally and become tension-free at the earliest.
  9. All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street.
  10. Exits shall be clearly visible and the route to reach such exits shall be clearly marked and signs posted to guide the occupants of the floor concerned. Signs shall be illuminated and wired to independent electrical circuits on an alternative source of supply.
  11. The sizes and colour of the exit signs shall be in accordance with established international practice.
  12. Normal colour used for exits is green. Illumination of exits and exit route signs, even when electricity is turned off, is very important to ensure orderly evacuation of occupants without chaos.
  13. The floors of areas covered for the means of exits shall be illuminated to values not less than 10 lux at floor level.
  14. This should cover all portions of exit access, exits and exit discharge.
  15.  Fire doors with 2 hour fire resistance shall be provided at appropriate places along the escape route and particularly at the entrance to lift lobby and stairwell, where a funnel or flue effect may be created inducing an upward spread of fire, to prevent spread of fire and smoke.

     The fire load
Fire load is usually expressed in terms of the “wood-equivalent” weight of combustible building contents per unit building- floor area in psf. The actual weight of combustible contents is adjusted to the wood-equivalent weight based on the estimated potential heat of contents normalized to the potential heat of wood (8000 Btu/lb). Alternatively, the fire load could be expressed in terms of the potential heat of building contents per unit building-floor area in Btu/ft2.

Knowing the fire load of rooms in a burning structure is important information for fire safety:-
  1. It indicates how destructive fires in different rooms or compartments can be.
  2. Gives an idea of how likely a fire is to spread from one area to another.
  3. Firefighters use this information to identify the most vulnerable or dangerous areas of burning buildings.
  4. It is also one consideration taken into account when a building is being constructed. For example, concrete does not contribute to fire load because it does not burn, and so is often used to construct rooms or building where highly flammable materials are kept.
  5. Fire codes and building codes often include regulations restricting where and how highly flammable materials such as fuel may be stored, because they greatly contribute to the local fire load and present a heightened risk of an out-of-control fire if kept in places with fire-control measures that were not designed to deal with the amount of heat they can generate.


Fire load can be caluclated as follows:-
Weight of the material in Kg (mass) X Calorific value of the material
Unit of fire load is in Kilo Joules.

For example 1 tonne of propane @ a calorific value of 47.3x10³ KJ/KG
= 1000 x 47.3 x 10³ = 47300 KJ

Structural Fire Protection
The structural elements of a building need to be designed to withstand the effects of building compartment fires, so as to minimize the likelihood of structural collapse. The use of steel framed construction and in particular the use of fireproofing materials is known to provide fire resistance levels for the steel elements of buildings.
Structural fire protection – what is it and why do we need it?
Steel structures, consisting of structural steel members, connections, fasteners and frames, act together in resisting imposed actions (loads, pressures, displacements, strains, etc). Load bearing steel framed buildings or building structures need to cater for all the loads that building can experience, including the dead load of the building itself, live loads applied to the building in use, wind and snow loading. We need to pay special attention to the fireproofing of steel framed buildings to ensure that during pre-determined fire scenarios that the steel does not get above critical temperatures
Fireproofing is achieved by applying fireproofing covering materials to thermally protect the underlying steel from the heat of the fire. The type and amount of fire proofing material is dependent on a number of variables, some of which include:
1.     size of steel members in question
2.     fire severity
3.     fire rating or duration of exposure to a given fire
4.     time of application of the fireproofing covering
5.     budget
6.     aesthetics
          7.    location of project
For the purposes of this article, fireproofing materials have been allocated in three (3) distinct generic categories which include:
1. conventional spray applied materials
2. board materials
3. intumescent paints
  
Structural integrity
Structural integrity and failure is an aspect of engineering which deals with the ability of a structure to support a designed load (weight, force, etc...) without breaking, tearing apart, or collapsing, and includes the study of breakage that has previously occurred in order to prevent failures in future designs.
Structural integrity is a performance characteristic which is applied to a component, a single structure, or a structure consisting of different components. Structural integrity is the quality of an item to hold together under a load, including its own weight, resisting breakage or bending. It assures that the construction will perform its designed function, during reasonable use, for as long as the designed life of the structure. Items are constructed with structural integrity to ensure that catastrophic failure does not occur, which can result in injuries, severe damage, death, or monetary losses.
Structural failure refers to the loss of structural integrity, which is the loss of the load-carrying capacity of a component or member within a structure, or of the structure itself. Structural failure is initiated when the material is stressed to its strength limit, thus causing fracture or excessive deformations. In a well-designed system, a localized failure should not cause immediate or even progressive collapse of the entire structure. Ultimate failure strength is one of the limit states that must be accounted for in structural engineering and structural design.
To construct an item with structural integrity, an engineer must first consider the mechanical properties of a material, such as toughness, strength, weight, hardness, and elasticity, and then determine a suitable size, thickness, or shape that will withstand the desired load for a long life. A material with high strength may resist bending, but, without adequate toughness, it may have to be very large to support a load and prevent breaking. However, a material with low strength will likely bend under a load even though its high toughness prevents fracture.
Failure of a structure can occur from many types of problems. Most of these problems are unique to the type of structure or to the various industries. However, most can be traced to one of five main causes.
·         The first, whether due to size, shape, or the choice of material, is that the structure is not strong and tough enough to support the load. If the structure or component is not strong enough, catastrophic failure can occur when the overstressed construction reaches a critical stress level.
·         The second is instability, whether due to geometry, design or material choice, causing the structure to fail from fatigue or corrosion. These types of failure often occur at stress points, such as squared corners or from bolt holes being too close to the material's edge, causing cracks to slowly form and then progress through cyclic loading. Failure general occurs when the cracks reach a critical length, causing breakage to happen suddenly under normal loading conditions.
·         The third type of failure is caused by manufacturing errors. This may be due to improper selection of materials, incorrect sizing, improper heat treating, failing to adhere to the design, or shoddy workmanship. These types of failure can occur at any time, and are usually unpredictable.
·         The fourth is also unpredictable, from the use of defective materials. The material may have been improperly manufactured, or may have been damaged from prior use.
·         The fifth cause of failure is from lack of consideration of unexpected problems. Vandalism, sabotage, and natural disasters can all overstress a structure to the point of failure. Improper training of those who use and maintain the construction can also overstress it, leading to potential failures.

Building fires due to electrical failures:

Modes of ignition
The examination of failures can be approached in several different ways:
(a) identifying the act(s) or omission(s) leading to failure
(b) classifying failures by the functional nature of the device or part thereof that failed
(c) studying the basic physics of failures.

A consideration of the failure mechanisms reveals that there are only a few main ways that electrical insulation, or combustibles close by to electric distribution components, can be ignited, although there are diverse aspects to each:
(1) arcing
(2) excessive ohmic heating, without arcing
(3) external heating.
Some ignition types involve a combination of mechanisms, so they must not be viewed as mutuallyexclusive causes of fire.

Arcing
The causes of arcs can be many, but the primary ones are:
(1) carbonization of insulation (arc tracking)
(2) externally induced ionization of air (created by flames or an earlier arc)
(3) short circuits

CARBONIZATION OF INSULATION
In 120/240 VAC circuits, it is not difficult to cause sustained arcing if there is a carbonized conductive path. This is sometimes called arcing-across-char. Insulating materials vary widely in their susceptibility to arc tracking. A large fraction of wiring in 120/240 V circuits is insulated with PVC, When PVC is exposed to temperatures of 200 . 300ºC, it chars and the char is a semiconductor. Not surprisingly, this can lead to leakage currents and arcing.

Following sequence of steps were identified:
  1. Initial current flow occurs due a carbonized layer.
  2. The current flow increases and results in local arcing
  3. The arcing causes melting of metal and expulsion of the molten pieces.
  4. Once the molten pieces are expelled, current flow drops
  5. Continued current flow through carbonized material eventually leads again to a sizeable current flow.


 EXTERNALLY-INDUCED IONIZATION OF AIR
The intrinsic dielectric strength of air is high (roughly 3 MV m-1, for all except very small gaps), but breakdown can occur at much lower values if the air space is ionized by some means. Two such means are flames and pre-existing arcs. If a serious arc-fault occurs in a distribution bus, a large amount of ionized gases will be ejected. These can travel a certain distance, and if they encounter another circuit, they can readily cause a breakdown and new arcing at the second location.

SHORT CIRCUITS
The term short circuit is commonly applied in the situation where a low-resistance, high-current fault suddenly develops in a circuit.
This can take two forms:
(1) a bolted short where a good metal-to-metal contact is made across a full-thickness section of metal;
(2) an arcing short, where initial metal-to-metal contact is not sustained and current flow through an arc.

An arcing short results from a momentary contact of two conductors. This causes melting of the
material around the contact area. Magnetic forces tend to push the conductors apart, and the liquid bridge between them then gets broken. Sparking may be observed as the conductors come apart.

Excessive ohmic heating
The causes of excessive ohmic heating can be subdivided into:
(1) gross overloads
(2) excessive thermal insulation
(3) stray currents and ground faults
(4) overvoltage
(5) poor connections

External heating
Most cases of external heating involve the wire or wiring device as .victim. of fire and not as the
initiator of fire. But some situations do exist where external heating of wiring serves as the initiating event. In many cases, arcing occurs after sufficient overheating.The electrical
failure of two cables as a function of oven heating. Electrical failure was considered to be a short circuit or a low-resistance condition developed across the line; experiments were not conducted to actually elicit ignitions. A cable with cross-linked polyethylene insulation failed at 270ºC, while a cable with polyethylene/PVC wire insulation and PVC jacket failed at 250ºC. A NIST study on lighting fixtures examined the effect of over-temperatures on 60ºC-rated normal building wiring. When overlamping of a fixture created 202-205ºC temperatures in the electrical junction box, failure occurred in less than 65 h. The wire insulation became brittle, cracked, fell away from the conductors, and this led to a short circuit.